-40%

10-20-25-40-50-100-50-100-200mA 0.25-0.5-1A E513 Milli Ammeter an-g Fluke

$ 58.08

Availability: 100 in stock
  • Condition: Used
  • All returns accepted: ReturnsNotAccepted
  • Brand: Fluke

    Description

    Milli ammeter E513
    ,
    analog of  Lutron,
    Advantest, Avtech,
    HP Agilent,
    NoiseCom,
    General Radio, Boonton, Anritsu, Fluke and general Electric, but  has the same or better characteristics.
    This device can be used for wide measurement
    range
    .
    For sale is 1 of 3 devices, please choose on from the table.
    Is designed to measure AC and DC power.
    Measurement range
    10mA, 20mA, 40mA, 25mA, 50mA, 100mA, 50mA, 100mA, 200mA, 0.25 A, 0.5 A, 1A, 0.25 A, 0.5 A, 1A
    Accuracy class
    0.5-1.0
    Milli ammeter E513
    (hereinafter - devices) are designed to measure AC and DC power. Devices can be used in industrial enterprises laboratories, research institutes, power grids, schools, etc.
    Devices are available in two versions:
    Devices E513 are designed for use in moderate climate conditions in dry heated rooms, with air temperature and relative humidity, shown in table 1.
    Devices
    E513T4.1
    (tropical version) are designed to be used indoors in both dry and humid tropical climate at an ambient temperature from 1 to 45 ° C and relative humidity up to 80% at 25 ° C.
    It is acceptable to use device in tropical climate – version TC, category 4.2 according to GOST 15150-69.
    Condition:
    NEW (not used, an old stock). Tested and 100% workable.
    If necessary, we can provide calibration certificate from Government standardization institute
    (+145-265usd).
    Also we can provide other resistance, capacitance and inductance standards, decade box and other etalons.
    Also we can provide other resistance, capacitance and inductance standards, decade box and other etalons.
    Please take a look on my other items!
    If you haven’t found the needed item in my listing, please contact me. I’ll try to help you.
    Technical
    characteristics of device
    Milli ammeter E513
    :
    Device acceptable basic error limit at temperature 20 ± 2 ° C at all elevations of working scale part in normal frequency range and at constant current does not exceed:
    ± 0.5% from final measurement range scale for devices E513/1-4
    ± 1% for modifications E513 / 5
    Technical characteristics of device modifications are shown in table 1.
    Measurements response time does not exceed 4 seconds at temperature from 15 to 20 ° C, when temperature is lowered to -50 ° C measurement time may increase to 18 seconds.
    Device acceptable additional error limit is equal to acceptable basic error limit at: rejection rate by ± 10% from normal frequency limits, frequency deviation from normal frequency limits to any frequency in operating frequency range.
    Device acceptable additional error limit  caused by changes in ambient temperature from normal (normal conditions in accordance with GOST 8711-78) to any temperature within operating temperature (table 1) for every 10
    ° C
    temperature change
    is equal to
    ± 0.5% of full measurement range scale.
    Dimensions and weight of devices do not exceed values
    shown
    in table 2.
    Table 1
    Device designation
    Modification
    Accuracy class according to GOST 8711-78
    Final measurement range value
    Normal frequency range, Hz
    Operating frequency range, Hz
    Using conditions
    Milli ammeter
    E
    513/1
    0
    .
    5
    10
    m
    А
    40-60
    -
    Temperature from 10 to 35 ° C. Relative humidity 80% (at 25 ° C).
    20
    m
    А
    60-200
    40
    m
    А
    60-400
    E
    513/2
    25
    m
    А
    40-100
    100-500
    50
    m
    А
    100-1000
    100
    m
    А
    3513/3
    50
    m
    А
    100
    m
    А
    100-2000
    200
    m
    А
    100-1000
    E
    513/4
    0
    .
    25А
    100-1500
    0
    .

    100-2000

    E
    513/5
    1
    .
    0
    0
    .
    25А
    40-1500
    1500-3000
    Temperature from -15 to +45 ° C. Relative humidity 90% (at 30 ° C).
    0
    .


    Table 2
    Device
    Designation
    Dimensions, mm
    Weight, kg
    Milli ammeter
    E
    513
    140x195x96
    1
    .
    3
    Warranty 12mounth.
    Delivery term
    This device is available in stock right now.
    I can send it at one day after your payment.
    But due to the fact, that this device is of high precision, it should be calibrated before shipping.
    I calibrate and test all my devices.  Calibration time may take from
    1-14 days.
    (depends on device, usually it takes
    3 days.
    ).
    I can send it at one day after your payment but without any calibration. Please chose.
    I can supply you such device of fresh years of manufacture
    2011-2012,
    but the price of such device will be approximately 20-40% higher or more.
    This device also can be named as:
    E 513
    ,
    E-513
    ,
    E513
    ,
    е
    513
    ,
    е513
    е-513
    .